TY - GEN
T1 - Automated detection and correction of eye blink and muscular artefacts in EEG signal for analysis of Autism Spectrum Disorder
AU - Jadhav, P. N.
AU - Shanamugan, D.
AU - Chourasia, A.
AU - Ghole, A. R.
AU - Acharyya, A.
AU - Naik, G.
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/11/2
Y1 - 2014/11/2
N2 - Autism Spectrum Disorder (ASD) is a neural development disorder affecting the information processing capability of the brain by altering how nerve cells and their synapses interconnect and organize. Electroencephalograph or EEG signals records the electrical activity of the brain from the scalp which can be utilized to identify and investigate the brain wave pattern which are specific to individuals with ASD. Therefore, the analysis of ASD can be done by scrutinizing the specific bands (Theta, Mu and Beta) of the EEG signal. However, EEG signals are mainly contaminated by Ocular (Eye-blink) and Myogenic artefacts which pose problems in EEG interpretation. In this paper an automated real-time method for detection and removal of Ocular and Myogenic artefacts for multichannel EEG signal is proposed which would enhance the diagnostic accuracy. The proposed methodology has been validated against 20 subjects from Caltech, Physionet, Swartz Center for Computational Neuroscience and the computed average correlation and regression are 0.7574 and 0.6992 respectively.
AB - Autism Spectrum Disorder (ASD) is a neural development disorder affecting the information processing capability of the brain by altering how nerve cells and their synapses interconnect and organize. Electroencephalograph or EEG signals records the electrical activity of the brain from the scalp which can be utilized to identify and investigate the brain wave pattern which are specific to individuals with ASD. Therefore, the analysis of ASD can be done by scrutinizing the specific bands (Theta, Mu and Beta) of the EEG signal. However, EEG signals are mainly contaminated by Ocular (Eye-blink) and Myogenic artefacts which pose problems in EEG interpretation. In this paper an automated real-time method for detection and removal of Ocular and Myogenic artefacts for multichannel EEG signal is proposed which would enhance the diagnostic accuracy. The proposed methodology has been validated against 20 subjects from Caltech, Physionet, Swartz Center for Computational Neuroscience and the computed average correlation and regression are 0.7574 and 0.6992 respectively.
UR - http://www.scopus.com/inward/record.url?scp=84976630213&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2014.6943977
DO - 10.1109/EMBC.2014.6943977
M3 - Conference contribution
C2 - 25570345
AN - SCOPUS:84976630213
T3 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
SP - 1881
EP - 1884
BT - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2014
Y2 - 26 August 2014 through 30 August 2014
ER -